IoTDB
IoTDB sink connector
Support Those Engines
Spark
Flink
SeaTunnel Zeta
Description
Used to write data to IoTDB.
Using Dependency
For Spark/Flink Engine
- You need to ensure that the jdbc driver jar package has been placed in directory
${SEATUNNEL_HOME}/plugins/
.
For SeaTunnel Zeta Engine
- You need to ensure that the jdbc driver jar package has been placed in directory
${SEATUNNEL_HOME}/lib/
.
Key Features
IoTDB supports the exactly-once
feature through idempotent writing. If two pieces of data have
the same key
and timestamp
, the new data will overwrite the old one.
There is a conflict of thrift version between IoTDB and Spark.Therefore, you need to execute rm -f $SPARK_HOME/jars/libthrift*
and cp $IOTDB_HOME/lib/libthrift* $SPARK_HOME/jars/
to resolve it.
Supported DataSource Info
Datasource | Supported Versions | Url |
---|---|---|
IoTDB | >= 0.13.0 | localhost:6667 |
Data Type Mapping
IotDB Data Type | SeaTunnel Data Type |
---|---|
BOOLEAN | BOOLEAN |
INT32 | TINYINT |
INT32 | SMALLINT |
INT32 | INT |
INT64 | BIGINT |
FLOAT | FLOAT |
DOUBLE | DOUBLE |
TEXT | STRING |
Sink Options
Name | Type | Required | Default | Description |
---|---|---|---|---|
node_urls | String | Yes | - | IoTDB cluster address, the format is "host1:port" or "host1:port,host2:port" |
username | String | Yes | - | IoTDB user username |
password | String | Yes | - | IoTDB user password |
key_device | String | Yes | - | Specify field name of the IoTDB deviceId in SeaTunnelRow |
key_timestamp | String | No | processing time | Specify field-name of the IoTDB timestamp in SeaTunnelRow. If not specified, use processing-time as timestamp |
key_measurement_fields | Array | No | exclude device & timestamp | Specify field-name of the IoTDB measurement list in SeaTunnelRow. If not specified, include all fields but exclude device & timestamp |
storage_group | Array | No | - | Specify device storage group(path prefix) example: deviceId = ${storage_group} + "." + ${key_device} |
batch_size | Integer | No | 1024 | For batch writing, when the number of buffers reaches the number of batch_size or the time reaches batch_interval_ms , the data will be flushed into the IoTDB |
max_retries | Integer | No | - | The number of retries to flush failed |
retry_backoff_multiplier_ms | Integer | No | - | Using as a multiplier for generating the next delay for backoff |
max_retry_backoff_ms | Integer | No | - | The amount of time to wait before attempting to retry a request to IoTDB |
default_thrift_buffer_size | Integer | No | - | Thrift init buffer size in IoTDB client |
max_thrift_frame_size | Integer | No | - | Thrift max frame size in IoTDB client |
zone_id | string | No | - | java.time.ZoneId in IoTDB client |
enable_rpc_compression | Boolean | No | - | Enable rpc compression in IoTDB client |
connection_timeout_in_ms | Integer | No | - | The maximum time (in ms) to wait when connecting to IoTDB |
common-options | no | - | Sink plugin common parameters, please refer to Sink Common Options for details |
Examples
env {
parallelism = 2
job.mode = "BATCH"
}
source {
FakeSource {
row.num = 16
bigint.template = [1664035200001]
schema = {
fields {
device_name = "string"
temperature = "float"
moisture = "int"
event_ts = "bigint"
c_string = "string"
c_boolean = "boolean"
c_tinyint = "tinyint"
c_smallint = "smallint"
c_int = "int"
c_bigint = "bigint"
c_float = "float"
c_double = "double"
}
}
}
}
Upstream SeaTunnelRow data format is the following:
device_name | temperature | moisture | event_ts | c_string | c_boolean | c_tinyint | c_smallint | c_int | c_bigint | c_float | c_double |
---|---|---|---|---|---|---|---|---|---|---|---|
root.test_group.device_a | 36.1 | 100 | 1664035200001 | abc1 | true | 1 | 1 | 1 | 2147483648 | 1.0 | 1.0 |
root.test_group.device_b | 36.2 | 101 | 1664035200001 | abc2 | false | 2 | 2 | 2 | 2147483649 | 2.0 | 2.0 |
root.test_group.device_c | 36.3 | 102 | 1664035200001 | abc3 | false | 3 | 3 | 3 | 2147483649 | 3.0 | 3.0 |
Case1
only fill required config.
use current processing time as timestamp. and include all fields but exclude device
& timestamp
as measurement fields
sink {
IoTDB {
node_urls = "localhost:6667"
username = "root"
password = "root"
key_device = "device_name" # specify the `deviceId` use device_name field
}
}
Output to IoTDB
data format is the following:
IoTDB> SELECT * FROM root.test_group.* align by device;
+------------------------+------------------------+--------------+-----------+--------------+---------+----------+----------+-----------+------+-----------+--------+---------+
| Time| Device| temperature| moisture| event_ts| c_string| c_boolean| c_tinyint| c_smallint| c_int| c_bigint| c_float| c_double|
+------------------------+------------------------+--------------+-----------+--------------+---------+----------+----------+-----------+------+-----------+--------+---------+
|2023-09-01T00:00:00.001Z|root.test_group.device_a| 36.1| 100| 1664035200001| abc1| true| 1| 1| 1| 2147483648| 1.0| 1.0|
|2023-09-01T00:00:00.001Z|root.test_group.device_b| 36.2| 101| 1664035200001| abc2| false| 2| 2| 2| 2147483649| 2.0| 2.0|
|2023-09-01T00:00:00.001Z|root.test_group.device_c| 36.3| 102| 1664035200001| abc2| false| 3| 3| 3| 2147483649| 3.0| 3.0|
+------------------------+------------------------+--------------+-----------+--------------+---------+---------+-----------+-----------+------+-----------+--------+---------+
Case2
use source event's time
sink {
IoTDB {
node_urls = "localhost:6667"
username = "root"
password = "root"
key_device = "device_name" # specify the `deviceId` use device_name field
key_timestamp = "event_ts" # specify the `timestamp` use event_ts field
}
}
Output to IoTDB
data format is the following:
IoTDB> SELECT * FROM root.test_group.* align by device;
+------------------------+------------------------+--------------+-----------+--------------+---------+----------+----------+-----------+------+-----------+--------+---------+
| Time| Device| temperature| moisture| event_ts| c_string| c_boolean| c_tinyint| c_smallint| c_int| c_bigint| c_float| c_double|
+------------------------+------------------------+--------------+-----------+--------------+---------+----------+----------+-----------+------+-----------+--------+---------+
|2022-09-25T00:00:00.001Z|root.test_group.device_a| 36.1| 100| 1664035200001| abc1| true| 1| 1| 1| 2147483648| 1.0| 1.0|
|2022-09-25T00:00:00.001Z|root.test_group.device_b| 36.2| 101| 1664035200001| abc2| false| 2| 2| 2| 2147483649| 2.0| 2.0|
|2022-09-25T00:00:00.001Z|root.test_group.device_c| 36.3| 102| 1664035200001| abc2| false| 3| 3| 3| 2147483649| 3.0| 3.0|
+------------------------+------------------------+--------------+-----------+--------------+---------+---------+-----------+-----------+------+-----------+--------+---------+
Case3
use source event's time and limit measurement fields
sink {
IoTDB {
node_urls = "localhost:6667"
username = "root"
password = "root"
key_device = "device_name"
key_timestamp = "event_ts"
key_measurement_fields = ["temperature", "moisture"]
}
}
Output to IoTDB
data format is the following:
IoTDB> SELECT * FROM root.test_group.* align by device;
+------------------------+------------------------+--------------+-----------+
| Time| Device| temperature| moisture|
+------------------------+------------------------+--------------+-----------+
|2022-09-25T00:00:00.001Z|root.test_group.device_a| 36.1| 100|
|2022-09-25T00:00:00.001Z|root.test_group.device_b| 36.2| 101|
|2022-09-25T00:00:00.001Z|root.test_group.device_c| 36.3| 102|
+------------------------+------------------------+--------------+-----------+
Changelog
2.2.0-beta 2022-09-26
- Add IoTDB Sink Connector